Skip to main content

A Company Connecting the Future of Industry Through Smart Heating Technology

HEATER JACKET CONTROLLER SPECIFICATIONS
Voltage Specifications Input Power 1 PHASE 100~240VAC 50/60Hz 75A
Heater Output Capacity MAX: 7A/1ch
Control Specifications Input Range 0–999°C K-type T/C Input
Control Type PID Control
Safety Specifications Overload Protection 1) Fuse cutoff if a channel exceeds 10A
2) ELCB cutoff if current exceeds 75A
Leakage Protection ELCB cutoff when leakage exceeds 100mA
HEATER Alarm 1) HIGH Alarm: Channel power cutoff (Lamp & Buzzer On)
2) HBA (Heater Break Alarm): Channel power cutoff (Lamp & Buzzer On)
3) LOW Alarm (Buzzer Only)
Additional Features Warning Output (Alarm) External Alarm Output (NO or NC)
Current Detection Heater Jacket current monitoring available
Telecommunications RS-485
TCU ON/OFF Function Individual TCU ON/OFF
Dimension & Weight W*D*H Customization